Asphyxiation prevention begins with an accurate and reliable room air oxygen monitor to assure personal safety.

Too often Nitrogen is the cause of Oxygen Depletion or Asphyxiation in the work place.

Nitrogen gas itself is not poisonous, as the air we breathe contains approximately 78% nitrogen, 20.9% Oxygen, and trace amounts of all other gases that make up the remaining 1%. However, if sufficient liquid nitrogen or other Cryogenic Material vaporizes from a pressurized container into a poorly ventilated work space it can easily reduce the oxygen level to below 20.0%.

Personnel in that space are in critical jeopardy due to rapid oxygen deprivation. Rapid venting can cause rapid displacement of normal air, leading to a local concentration of nearly 100% nitrogen or other Cryogenic Material.

Inert gas asphyxiation is a form of asphyxiation which results from breathing a physiologically inert gas in the absence of oxygen, or a low amount of oxygen, rather than atmospheric air. Examples of physiologically inert gases, which have caused accidental or deliberate death by this mechanism, are argon, helium and nitrogen. The term "physiologically inert" is used to indicate a gas which has no toxic or anesthetic properties and does not act upon the heart or hemoglobin. Instead, the gas acts as a simple diluent to reduce oxygen concentration in inspired gas and blood to dangerously low levels, thereby eventually depriving all cells in the body of oxygen.

According to the U.S. Chemical Safety and Hazard Investigation Board, in humans, "breathing an oxygen deficient atmosphere can have serious and immediate effects, including unconsciousness after only one or two breaths. The exposed person has no warning and cannot sense that the oxygen level is too low.

Make sure you purchase the highest quality and reliable oxygen analyzer for you employee safety and wellbeing.

Model 2010BR

Hazardous area permanent mount trace oxygen analyzer

  • Trace oxygen - 0.0ppm to 25.0%
  • Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
  • Hazardous area - CSA approved Class 1 Division 1 Group BCD
  • Patented cell block minimizes sample volume, fittings and eliminates tubing.
  • Compact size - easy installation
  • AC/DC operation with very low power
  • Integrated high-efficiency low power heater optional
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 1-5V or 4-20mA output user selectable
  • 10 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of oxygen readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 1000RS

Hazardous area portable trace oxygen analyzer

  • Trace oxygen - 0.00ppm to 25.0%
  • Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
  • Portable, battery powered
  • Patented cell block minimizes sample volume, fittings and eliminates tubing.
  • Integrated 4-way seal-off/bypass valve protects sensor from air contamination and purges system prior to measurement
  • Fastest come-down (time to measurement) in the industry
  • Precision state-of-the-art electronics
  • Data logging of oxygen readings, temperature and power supply voltage
  • 10 user-selectable analog output ranges
  • Calibration history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 210BR

Hazardous area permanent mount percent oxygen analyzer

  • Percent oxygen - 0.00% to 25.0%
  • H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
  • Hazardous area - CSA approved Class 1 Division 1 Group BCD
  • Patented cell block minimizes sample volume, fittings and eliminates tubing.
  • Compact size - easy installation
  • AC/DC operation with very low power
  • Integrated high-efficiency low power heater optional
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 1-5V or 4-20mA output user selectable
  • 4 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of oxygen readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 3010BR

Hazardous area permanent mount hydrogen sulfide analyzer

  • Trace hydrogen Sulfide
  • 0-200ppm standard, 0-2000ppm optional
  • Hazardous area - CSA approved Class 1 Division 1 Group BCD
  • Patented cell block minimizes sample volume, fittings and eliminates tubing.
  • Compact size - easy installation
  • AC/DC operation with very low power
  • Integrated high-efficiency low power heater optional
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 1-5V or 4-20mA output user selectable
  • 4 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of hydrogen sulfide readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 3000RS

Hazardous area portable hydrogen sulfide analyzer

  • Trace hydrogen Sulfide
  • 0-200ppm standard, 0-2000ppm optional
  • Portable, battery powered
  • Patented cell block minimizes sample volume, fittings and eliminates tubing.
  • Precision state-of-the-art electronics
  • Data logging of hydrogen sulfide readings, temperature and battery voltage
  • 4 user-selectable analog output ranges
  • Calibration history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 2001RS

General purpose permanent mount trace oxygen analyzer

  • Trace oxygen - 0.00ppm to 25.0%
  • Ultra-fast come-down sensor
  • Positive pressure sample
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Sensor sealed off on power failure - protects against air contamination
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 10 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 2001RSP

General purpose permanent mount trace oxygen analyzer. Atmospheric pressure sample source

  • Trace oxygen - 0.00ppm to 25.0%
  • Ultra-fast come-down sensor
  • Ambient pressure sample
  • Built-in pump
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Sensor sealed off on power failure - protects against air contamination
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 10 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 201RS

General purpose permanent mount percent oxygen analyzer

  • Percent oxygen - 0.00% to 25.0%
  • Optional ranges 0-1000ppm, 0-50%, 0-100%
  • Optional sensors for inert gas or High level CO2-containing gases
  • Positive pressure sample
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 4 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 201RSP

General purpose permanent mount percent oxygen analyzer. Atmospheric pressure sample source

  • Percent oxygen - 0.00% to 25.0%
  • Optional ranges 0-1000ppm, 0-50%, 0-100%
  • Optional sensors for inert gas or High level CO2-containing gases
  • Ambient pressure sample
  • Built-in pump
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 4 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Datalogging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 2001RSM

Multichannel general purpose permanent mount trace oxygen analyzer

  • Trace oxygen - 0.00ppm to 25.0%
  • Ultra-fast come-down sensor
  • Positive pressure sample
  • Up to 5 sequenced sample inputs
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Sensor sealed off on power failure - protects against air contamination
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 10 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 2001RSPM

Multichannel general purpose permanent mount trace oxygen analyzer for atmospheric pressure samples

  • Trace oxygen - 0.00ppm to 25.0%
  • Ultra-fast come-down sensor
  • Ambient pressure sample
  • Up to 5 sequenced sample inputs
  • Built-in pump
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Sensor sealed off on power failure - protects against air contamination
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 10 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 201RSM

Multichannel general purpose permanent mount percent oxygen analyzer

  • Percent oxygen - 0.00% to 25.0%
  • Optional ranges 0-1000ppm, 0-50%, 0-100%
  • Optional sensors for inert gas or High level CO2-containing gases
  • Positive pressure sample
  • Up to 5 sequenced sample inputs
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 4 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 201RSPM

Multichannel general purpose permanent mount percent oxygen analyzer for atmospheric pressure samples

  • Percent oxygen - 0.00% to 25.0%
  • Optional ranges 0-1000ppm, 0-50%, 0-100%
  • Optional sensors for inert gas or High level CO2-containing gases
  • Ambient pressure sample
  • Up to 5 sequenced sample inputs
  • Built-in pump
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Compact size - easy installation
  • AC power 90/240VAC
  • Precision state-of-the-art electronics
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Isolated 4-20mA output
  • 4 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Watchdog

Low cost Division 2 area permanent mount trace oxygen analyzer

  • Trace oxygen - 0.00ppm to 25.0%
  • Ultra-fast come-down H2S resistant sensor - up to 10ppm H2S resistant standard, 500ppm H2S resistant optional
  • Designed to meet Class 1 Division 2 hazardous area requirements
  • Patented cell block minimizes sample volume, fittings and eliminates tubing.
  • Compact size - easy installation
  • DC operation with low power
  • Precision state-of-the-art electronics
  • Isolated 1-5V or 4-20mA output user selectable
  • 10 user-selectable analog output ranges
  • Complete ModBus RTU supported over RS485
  • Data logging of oxygen readings, temperature and power supply voltage
  • Calibration, power failure and brownout history
  • Calibration factor indicates remaining sensor life
  • Electrochemical Sensor Based Technology

Model 2001LC

General purpose rack mount trace oxygen analyzer

  • Trace oxygen – 0.00ppm to 25.0%
  • Ultra-fast come-down sensor
  • Positive pressure sample
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Compact size – easy installation
  • DC power 10-28VDC
  • Low power
  • Precision state-of-the-art electronics
  • Isolated 4-20mA output
  • 10 user-selectable analog output ranges
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Electrochemical Sensor Based Technology

Model 221R

Area safety - permanent mount oxygen deficiency monitor

  • Oxygen deficiency monitor, 0.00-25.0% O2
  • CE marked, CSA approved
  • Long life (10 year) ultra-stable zirconium oxide sensor
  • Remote sensor option with digital communication
  • Insensitive to barometric pressure or temperature changes - no false alarms
  • AC power - 100-240V
  • Internal battery backup
  • Isolated 4-20mA output
  • OSHA specified alarm set points with audible alarm and relay contacts
  • Alarm upon enriched oxygen at 23.5%
  • Data logging of readings, temperature and power supply voltage
  • Calibration history
  • Zirconium Oxide Sensor Based Technology

Model 221R w/remote

Area safety – wall mount oxygen deficiency monitor

  • Oxygen deficiency monitor, 0.00-25.0% O2
  • CE marked, CSA approved
  • Long life (10 year) ultra-stable zirconium oxide sensor in remotely mounted probe
  • RS485 link between analyzer and probe for low interference
  • Remote sensor option with digital communication
  • Insensitive to barometric pressure or temperature changes – no false alarms
  • AC power – 100-240V
  • Internal battery backup
  • Isolated 4-20mA output
  • OSHA specified alarm set points with audible alarm and relay contacts
  • Alarm upon enriched oxygen at 23.5%
  • Data logging of readings, temperature and power supply voltage
  • Calibration history
  • Zirconium Oxide Sensor Based Technology

Model 201LC

General purpose rack mount percent oxygen analyzer

  • Percent oxygen – 0.00% to 25.0%
  • Positive pressure sample
  • Patented cell block minimizes sample volume, fittings and tubing.
  • Compact size – easy installation
  • DC power 10-28VDC
  • Low power
  • Precision state-of-the-art electronics
  • Isolated 4-20mA output
  • 4 user-selectable analog output ranges
  • Fully Programmable alarm logic (alarm delays, hold-off, etc.) with relay contacts
  • Electrochemical Sensor Based Technology

Model 60