The development of the AMI
Model 2010BR trace oxygen analyzer
began with a collection of inputs from
hundreds of industry leading engineers
and field technicians in the natural
gas and Petrochemical business.
These inputs coupled with our advanced
engineering techniques have resulted
in a totally complete, compact, and
versatile oxygen analyzer that can truly
be defined as state-of-the-art where
oxygen analysis is required in flammable
gas streams.
If necessary, the Model 2010BR oxygen
analyzer can be mounted directly outside
in all types of weather. An optional
high-tech, low power proportional temperature
controlled heater allows for an expanded
temperature range of -40 to 115 F without
an additional enclosure or wiring. This
applies in either Class 1, Div. 1 or
Div. 2 Groups B,C,D, area classifications.
The rugged, compact, complete oxygen
analyzer allows for quick and simple
installation resulting in big savings.
Click
Here For a Free Quote
|
AMI's advanced microprocessor
based electronics platform solves all known
application requirements without adding
additional costly components.
For example:
- High-resolution
single range LCD. Immediately reads
from .01ppm to 25% without range changing
delays or the need for manual adjustments
- Microprocessor
pulsed latching alarm relays. The
latching relay is pulsed by the microprocessor
controlling the logic state to either
open or closed. This eliminates a continuous
power drain when using a solar panel and
battery for power.
- Programmable
alarm delays:
Settings range from 0-300min. This feature
prevents alarm conditions due to quick
oxygen spikes or short-term operator error.
- User
selectable alarm setting:
Latching, non-latching, fail safe non-failsafe
- 10-User
selectable output ranges:
0-10ppm, 0-50ppm, 0-100ppm,
0-500ppm, 0-1000ppm, 0-.500%,
0-1%, 0-5%, 0-10%
and an air calibration range of 0-25%
- Alarm
hold off button:
Prevents false alarms when routinely calibrating
and allows you to immediately silence
(for a user programmable period
of time of 0-120min.) an alarm condition
when necessary at the touch of a button.
- Data
logger.
Logs data for 15 days @ 1min intervals
and 30 days @ 2min. intervals, etc.
- Complete
security feature:
Front panel settings will not respond
to unwanted tampering if the security
feature has been initiated via. laptop
computer.
- Two
standard isolated outputs
to chose from:
1-5VDC and 4-20ma.
- Available in A/C or
DC power
|
The
2010BR incorporates our advanced patented
cellblock technology consisting of a single
compact metallic block that undergoes a
complex machining process, followed with
corrosion-resistant nickel plating. The
block contains a series of drilled gas passages
eliminating the need for long lengths of
tubing and compression fittings.
A metering valve, flow meter
and a 3-way sample/span/shut off valve
are also an integral part of the cellblock.
This sophisticated design results in a
quicker up and down scale response times
and eliminates potential leak sources.
When the application
requires, we can provide a one of our
patent pending H2S resistant oxygen sensors
(up to 500ppm H2S exposure for its warranted
life) to meet your needs. This break through
sensor technology eliminates the need
for maintenance intensive H2S scrubbers.
 |
 |
|
AMI
guarantees
higher quality and exceptional
services
at a lower price.
REQUEST
QUOTE
Or
call us at:
714.848.5533
|
|
 |
 |
The front panel sensor access makes oxygen
sensor installation or replacement quick
and easy. It also allows for a rapid,
accurate calibration on ambient air (20.9%)
without the use of tools. A span gas port
comes standard for those who prefer a
certified span gas calibration.
Our advanced design approach has separated
us from the competition with the highest
performance, yet lowest cost trace oxygen
analyzer in the industry.
|
|
|
|
|
|
- 10-
User selectable analog output
ranges:
0-10ppm, 0-50ppm, 0-100ppm,
0-500ppm,
0-1000ppm, 0-.500%, 0-1%,
0-5%,
0-10%, and a calibration
range of 0-25%
- Sensitivity:
0.5% Full scale
- Repeatability:
±1% of full scale
at constant
temperature (on 10ppm output
range the
repeatability is ±3%
of scale)
- Display:
High resolution single range
3½ digit LCD
- Operating
temperature range:
32-115°F non heated
-40-115 °F with optional
heater
- Diurnal
temperature specification:
32-115°F, < ±3
of scale
-40-115 °F with optional
heater < ±3 of
scale
- 90%
Upscale Response times:
100ppm-25% less than 10
sec
0-10ppm less than 25 sec
0-5ppm less than 50 sec.
- Alarms
(standard):
2-Fully adjustable oxygen
concentration alarm set
points. Dry contacts 5A.
- Isolated
output signals: 1-5VDC,
and 4-20ma.
- Power
requirements:
10-28VDC or 115VAC
< 40mA (non heated).
24 Watts approx. with heated
option
- Mounting:
Wall mount or 2" pipe
- Area
classification:
Designed for use in Class
I, Div. I, Groups BCD
- Dimensions
: 13.00W x 9.50H x 5.00D
- Weight:
13 lbs
- Sensor
access: Easy, direct
front panel access
- Sample
connections: 316
Stainless steel ¼"
Compression
- Wetted
parts:
Nickel-plated metallic
|

- Designed to meet UL-913
and UL-1203
- Class I, Div. I.,
Groups BCD with flammable
sample. Approval pending.
- High resolution single
range 3 ½ LCD
- 10-User selectable
output ranges
- 2-Fully adjustable
oxygen concentration
alarms. Form C relay
contact closures
- Programmable alarm
delays. 0-300min.
- Alarm hold off: Programmable
0-120min.
- Data logger
- RS232 bi-directional
communications
- Isolated outputs:
1-5VDC, or 4-20ma.
- Power requirements:
10-28VDC or 115VAC
< 40mA (non heated).
24 Watts approx. with
heated option
- Direct, easy front-panel
sensor access
- Wall mount or 2"
pipe mount
- Compact size
- Nickel-plated cellblock,
316 stainless steel
fittings
- 2-Year warranty (excluding
sensor)
- No calibration or
support gases necessary
- Virtually unaffected
by hydrocarbons and
other oxidizable gases
- RFI protected
- Unaffected by change
in flow rate (0.1-5.0
SCFH)
|
|
|
|
|
|
|
|
|
|
|
|
|