AMI
Model 2001R series offers
a complete line of trace oxygen
analyzers utilizing a new modular
approach. With our recent engineering
breakthroughs, we can now provide
simple and user-friendly solutions
for a variety of applications. This
includes a single gas stream measurement
or sequenced multiple gas stream
measurements for either positive
pressure or ambient pressure requirements.
We have
outfitted the 2001R series with
a comprehensive state-of-the art
electronics and complete sample
handling package using our patent
pending cell block technology.
Our advanced
modular approach allows the 2001R
series to tackle any combination
of requirements while maintaining
the same compact panel mount dimensions
of 9.0"W x 5.0"H x 6.5"D.
The standard
electronics features include:
-
2-Fully
adjustable oxygen concentration
alarm
set points.
Form C contacts rated @ 5 amps.
-
Programmable
alarm delays:
delay settings range
from 0-300min. This feature prevents
nuisance
alarms due to quick oxygen spikes
or short-term
operator error.
-
User
configurable alarm setting:
alarm logic
choices include latching, non-latching,
fail-safe, and
non-failsafe.
Click Here For a Free Quote |
-
10-User
selectable output ranges: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm,
0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
an air calibration
range of 0-25%
-
Programmable
hold off/alarm bypass button:
prevents false alarms while
performing monthly
calibrations. Allows the technician
to bypass both
alarms for a user selectable
time of 0-120 min.
-
High-resolution
single range LCD:
rapidly reads
from 0.00ppm to 25.0% without
LCD range changing delays or
the need for manual range switch
adjustments.
-
Data
logger:
logs data for 15 days @ 1min
intervals, 30 days @ 2 min intervals,
etc.
-
Sensor
calibration factor: indicates
remaining
sensor life.
-
Three-user
selectable security levels:
allows
complete front panel access,
span only access, or no front
panel access.
-
Isolated
4-20mA. output.
-
Simple,
intuitive user interface.
The 2001R series offers
the following range of options while
maintaining the compact dimensions
previously described:
- Model
2001RS: Comprehensive electronics
package with complete sample system
for a single positive pressure gas
stream, including: flow control
valve, flow meter, internal solenoid
valves for shut off and sample/span
gas selection.
- Model
2001RSP: Comprehensive electronics
package with complete sample system
for a single ambient pressure to
low-pressure application. Sample
system includes: long life sample
pump, flow control valve, flow meter,
internal span gas and shut off solenoid
valves.
- Model
2001RSM: Comprehensive electronics
package with complete sample system
for up
to 5 separate positive pressure
gas streams, including: flow control
valve, flow meter and internal solenoid
valves for programmable 5-channel
sequencer.
- Model 2001RSPM:
Comprehensive electronics package
with complete sample system for
up to 5 separate ambient pressure
to low-pressure gas streams. Sample
system includes: long life sample
pump, flow control valve, flow meter
and internal solenoid valves for
programmable 5-channel sequencer.
|
MODEL
2001R SERIES
AMI's patented
cellblock begins with a single compact
metallic block that undergoes a complex
machining process, followed with corrosion-resistant
nickel plating. The block contains
a series of drilled intersecting gas
passages and mounted directly on it
are: a custom designed flow control
valve, flow meter, internal span gas
and isolation gas solenoid and compression
fittings. All become an integral part
of the
cellblock.
This eliminates the
techniques used by competitors of
piecing several lengths of tubing
between numerous compression fittings,
valving and a flow meter. In using
this approach, they add many potential
leak paths, increase response times
and the need for additional space.
Lastly, our front panel
sensor access makes O2 sensor installation
or replacement quick and easy without
tools or the need to remove any sensitive
components. This process takes less
than one minute!!
Our advanced design
approach has separated us from the
competition with the highest performance,
yet lowest cost oxygen analyzer in
the industry.
 |
 |
|
AMI
guarantees higher
quality and exceptional
services at a lower
price.
REQUEST
QUOTE
Or
call us at: 714.848.5533
|
|
 |
 |
|
|
|
|
|
|
|
|
- 10 user selectable output
ranges to choose from
- High resolution 3 ½
digit LCD
- 2 fully adjustable oxygen
concentration alarms
- Alarm delays
- Alarm hold off/Bypass
- RFI protected
- 4-20mA. isolated analog
output signal
- Data logger
- RS-232 bi-directional
communication for advanced
features
- Advanced analog output
calibration feature
- Power requirements: 115/230VAC
power
- Low minimum detection
limit
- Excellent repeatability
- Fast upscale/downscale
response times
- Single gas or multiple
gas streams for positive
pressure
- Single gas or multiple
gas streams for atmospheric
pressure
- Patented Cellblock Technology:
Allows for all components
such as: needle valve, flow
meter, miniature electronic
controlled gas and span
solenoid valving, compression
fittings to be an integral
part of the cellblock, eliminating
long lengths of tubing and
fittings.Other benefits
of this design include:
compact size, faster response
times and front panel sensor
access without the need
for tools.
- Area Classification: Designed
to meet General Purpose
requirements
- Unaffected by changes
in flow rate from 0.1 to
2.0 SCFH
- Panel mount
- Compact size
- 2 year warranty for analyzer,
parts and labor
- 6 month sensor warranty,
life expectancy 1-2 years
|
- 10
user selectable output ranges
to choose from: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm,
0-1000ppm, 0-.500%, 0-1%,
0-5%, 0-10% and 25%
The user selection of
an output range simultaneously
controls the two alarms,
the analog output and the
data logger so that all
4 functions operate on the
same range
- Digital
display: High resolution
3 ½ digit LCD. Reads
full scale from 0.00ppm
to 25.0% independently of
output range selection
- Alarms:
2 fully adjustable oxygen
concentration alarms
Dry contacts 5A. @24VDC/115VAC
- Alarm
delays: Programmable
from 0-300 minutes
- Alarm
hold off: Programmable
from 0-120 minutes
- Isolated
analog output signal:
4-20mA
Represents the output range
selected:
0-10ppm, 0-50ppm, 0-100ppm,
0-500ppm, 0-1000ppm, 0-.500%,
0-1%, 0-5%, 0-10% and 25%
- Data
logger: Logs data
for 15 days @ 1 minute intervals,
30 days @ 2 minute intervals,
etc.
Represents the output range
selected: 0-10ppm, 0-50ppm,
0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10%
and 25%
- Power
requirements: 115VAC/230,
3-10watts depending on 2001R
model selected
- Minimum
detection:
50ppb of oxygen
- Repeatability:
+/- 1% of range or +/- 0.2ppm
of oxygen, whichever is
greater
- Operating
temperature range:
32° to 115° F
- Diurnal
temperature specification:
< +/- 3 % of scale over
temperature range
- 90%
upscale response times:
10ppm - 25% <10 seconds
0-10ppm < 25 seconds
Typical downscale response:
1 minute exposure to air
down to 10ppm: < 15 minutes
- Area
Classification: Designed
to meet General Purpose
requirements
- Inlet
gas pressure for Model 2001RS
and Model 2001RSM:
0.5 to 30psig
Model
2001RS is for use
in a single gas stream only
Model
2001RSM is for use
in 1-5 multi gas streams
with built-in programmable
sequencer
- Inlet
gas pressure for Model 2001RSP
and Model 2001RSPM:
atmospheric pressure
Model
2001RSP is for use
in a single gas stream drawing
from atmospheric pressure
Model
2001RSPM is for use
1-5 multi gas streams with
built-in programmable sequencer
drawing from atmospheric
pressures
- Expected
pump life for Models 2001RSP
and 2001RSPM: 2+
years
- Gas
connections: ¼"
316 S.S. compression fittings
- Wetted
parts: 316 S.S. fittings,
electroless nickel plated
cellblock, gold plated contacts,
acrylic flow meter and Viton
O-rings
- Unaffected
by changes in flow rate
from 0.1 to 2.0 SCFH
- Mounting:
panel mount
- Dimensions:
9.0"W x 5.0"H
x 6.5"D
- Weight:
8-10 lbs. depending on 2001R
model selected
|
|
|
|
|
|
|
|
|
|
|
|
|