AMI has
provided yet another breakthrough
for portable trace oxygen analysis.
The patented cellblock technology
and abundance of standard electronics
features have resulted in a state-of-the-art
package.
The Model
1000RS utilizes our innovative
patented cellblock technology that
eliminates the need for the traditional,
individual sample system components
that are typically pieced together
using tubing, compression fittings,
valves and flow meters.
Our approach
begins with a compact solid metallic
block, which undergoes a complex machining
process, followed with corrosion-resistant
nickel plating. The block contains
a series of internal drilled gas passages,
replacing external tubing and compression
fittings.
The process
includes sophisticated machined ports
that accommodate a fine metering valve,
4-way selector valve, an oxygen sensor
and flow meter, keeping all components
integral to the block.
The unique
4-way selector valve offers many distinct
advantages:
- It opens or closes
both the sample gas inlet and exhaust
ports simultaneously with a simple
90° rotation.
- In the "OFF"
position the sensor is completely
sealed from the outside air (20.9%
oxygen) during long distance travels
between measurement sites, increasing
sensor life and responsiveness.
- The "OFF"
position also acts as a sample gas
bypass, further protecting the sensor
from exposure to high oxygen levels
during the initial connection from
the sample point to the analyzer.
- After making a simple
gas connection and using the purge
feature, simply rotate the selector
valve 90° which opens both the
"Sample Gas In" and "Exhaust"
ports simultaneously, and watch
how fast the Model 1000RS responds.
- No more confusing
quick disconnect logic.
When the application
requires, we can provide one of our
patent-pending H2S resistant oxygen
sensors (up to 500ppm H2S exposure
for its warranted life) to meet your
needs. This breakthrough sensor technology
eliminates the need for maintenance
intensive H2S scrubbers.
Click
Here For a Free Quote |
The 1000RS
has been designed for intrinsically
safe use in flammable gases and is
equipped with numerous standard electronic
features listed:
- State-of-the-art
microprocessor based electronics.
- High-resolution
single range LCD immediately
reads from 0.00ppm to 25% without
range changing delays or the need
for manual adjustments.
- Data logger:
logs data for 15 days at 1min intervals,
30 days at 2min intervals, etc.
- 0-1VDC analog
output.
- 10 user-selectable
analog output ranges: 0-10ppm,
0-50ppm, 0- 100ppm, 0-500ppm, 0-1000ppm,
0-0.500%, 0-1%, 0-5%, 0- 10% and
an air calibration range of 0-25%
- Complete security
feature: front panel settings
will not respond to tampering if
the security feature has been initiated
via laptop computer.
- Rechargeable NiCad
batteries: operates for 350
hours continuously.
- Low Battery indicator
- Built in trouble-shooting
diagnostics
- Cal Factor
- determines remaining O2 sensor
life
The front
panel sensor access makes sensor installation
or replacement quick and easy. It
also allows for a rapid, accurate
calibration using ambient air (20.9%)
if desired without the need for span
gas. For those who wish to use certified
span gas, simply connect the span
gas to the sample gas port, briefly
purge using the 4-way selector valve,
rotate the selector valve 90°
to the "Open" position;
the reading will rapidly stabilize
and you use the intuitive front panel
interface to instantly adjust the
reading.
No
other portable trace O2 analyzer on
the market compares in the areas of
accuracy, reliability, response time,
ease of use, desirable features, compact
size and low cost.
 |
 |
|
AMI
guarantees higher
quality and exceptional
services at a lower
price.
REQUEST
QUOTE
Or
call us at: 714.848.5533
|
|
 |
 |
|
|
|
|
|
|
|
|

-
10
user selectable output
ranges to choose from
-
High
resolution 3 ½
digit LCD
-
-
-
-
RS-232
bi-directional communication
for advanced features
-
Power
requirements: 115/230VAC
to 12VDC battery charger
-
Low
minimum detection
limit
-
-
Extended
operating temperature
range
-
Fast
upscale/downscale
response times
-
Patented
Cellblock Technology:
Allows for all components
such as: needle valve,
flow meter, 4-way
Sample/Bypass/On/Off
and compression fittings
to be an integral
part of the cellblock,
eliminating long lengths
of tubing and fittings.
Other benefits of
this design include:
compact size, faster
response times and
front panel sensor
access without the
need for tools.
-
Area
Classification: Designed
for intrinsic safety
for Class 1, Div.
1, Groups B,C,D
-
Unaffected
by changes in flow
rate from 0.1 to 2.0
SCFH
-
-
2
year warranty for
analyzer parts and
labor
-
6
month sensor warranty,
life expectancy 1-2
years
|
- 10
user selectable output
ranges to choose from:
0-10ppm, 0-50ppm, 0-100ppm,
0-500ppm, 0-1000ppm, 0-.500%,
0-1%, 0-5%, 0-10% and
25%
The user selection of
an output range simultaneously
controls the analog output
and the data logger so
that both functions operate
on the same range
- Digital
display: High resolution
3 ½ digit LCD.
Reads full scale from
0.00ppm to 25.0% independently
of output range selection
- Analog
output signal:
0-1VDC
- Represents
the output range selected:
0-10ppm, 0-50ppm, 0-100ppm,
0-500ppm, 0-1000ppm, 0-.500%,
0-1%, 0-5%,
0-10% and 25%
- Data
logger: Logs data
for 15 days @ 1 minute
intervals, 30 days @ 2
minute intervals, etc.
Represents the output
range selected: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm,
0-1000ppm, 0-.500%, 0-1%,
0-5%, 0-10% and 25%
- Power
requirements: 115/230VAC
to 12VDC battery charger
Rechargeable NiCad batteries,
350 hours continuous
- Minimum
detection:
50ppb of oxygen
- Repeatability:
+/- 1% of range or +/-
0.2ppm of oxygen, whichever
is greater
- Operating
temperature range:
25° to 115° F
- Diurnal
temperature specification:
< +/- 3 % of scale
over temperature range
- 90%
upscale response times:
10ppm - 25% <10 seconds
0-10ppm < 25 seconds
Typical downscale response:
1 minute exposure to air
down to 10ppm: < 15
minutes
- Area
Classification:
Designed for intrinsic
safety for Class 1, Div.
1, Groups B,C,D
- Inlet
gas pressure: 0.5
to 150psig
- Gas
connections: ¼"
quick disconnect 316 S.S.
compression fitting
- Wetted
parts: 316 S.S.
fittings, electroless
nickel plated cellblock,
gold plated contacts,
acrylic flow meter and
Viton O-rings
- Unaffected
by changes in flow rate
from 0.1 to 2.0 SCFH
- Portable
dimensions: 4.5"W
x 9.5"H x 4.5"D
- Weight:
5 lbs.
|
|
|
|
|
|
|
|
|
|
|
|
|