Model
1000RS
click
photos for larger view
|
|
|
| |
|
Portable Trace Oxygen Analyzer
With
Complete Sample System
|
| |
|
High-resolution single range
LCD
|
| |
|
10-user selectable
analog output ranges for data
logger or 0-1VDC: 0-10ppm, 0-50ppm,
0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
an air cal. range of 0-25% |
| |
|
0-1VDC analog
output |
| |
|
Data logger. Logs
data for 15 days @ 1min intervals,
30 days @ 2min intervals, etc |
| |
|
Patented cellblock technology
|
| |
|
Integral 4-way
gas selector valve with quick
disconnect fitting: Sample, Bypass,
Off. This revolutionary cellblock
design shuts or opens both "Sample
Gas In" and "Exhaust"
ports simultaneously in the "Off/On"
position so as not to back pressure
and damage the sensor. |
| |
|
Integral needle
valve and flow meter |
| |
|
1-2 year life electrochemical
sensor |
| |
|
Rechargeable NiCd
batteries |
| |
|
Very compact and
rugged |
| |
|
Designed for intrinsic
safety |
| |
|
|
|
|
|
|
|
|
 |
 |
Model
2001RS
click
photos for larger view
|
|
|
| |
|
Panel Mount Trace Oxygen Analyzer
With Sample System |
| |
|
High resolution single range
LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
10- User selectable
analog output ranges: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and flow meter
|
| |
|
Span gas and shut
off solenoid valves |
| |
|
Patented cellblock
technology |
| |
|
General Purpose |
| |
|
|
|
|
|
|
|
|
 |
 |
Model
2001RSP
click
photos for larger view
|
|
|
| |
|
Panel Mount Trace Oxygen Analyzer
With Sample System
|
| |
|
High resolution single range
LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
10- User selectable
analog output ranges: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and flow meter
|
| |
|
Span gas and shut
off solenoid valves |
| |
|
Long life sample
pump |
| |
|
Patented cellblock
technology |
| |
|
General Purpose |
| |
|
|
|
|
|
|
|
|
 |
 |
Model
2001RSM
click
photos for larger view
|
|
|
| |
|
Panel Mount Trace Oxygen Analyzer
With Sample System |
| |
|
High resolution single range
LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
10- User selectable
analog output ranges: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and
flow meter |
| |
|
5- port solenoid valves
|
| |
|
5-point programmable
sequencer |
| |
|
Patented cellblock
technology |
| |
|
General Purpose |
| |
|
|
|
|
|
 |
 |
Model
2001RSPM
click
photos for larger view
|
|
|
| |
|
Panel Mount Trace Oxygen Analyzer
With Complete Sample System |
| |
|
High resolution single range
LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
Standard analog
output ranges: 0-10ppm, 0-50ppm,
0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and
flow meter |
| |
|
5- port solenoid valves
|
| |
|
5-point programmable
sequencer |
| |
|
Long life sample
pump |
| |
|
Patented cellblock
technology |
| |
|
General Purpose |
| |
|
|
|
|
|
|
 |
 |
Model
2010BR
click
photos for larger view
|
|
|
| |
|
Wall Mount Trace Oxygen Analyzer
With
Complete Sample System |
| |
|
High resolution
single range LCD |
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
10- User selectable
analog output ranges: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
an air cal. range of 0-25% |
| |
|
Isolated 1-5VDC
and 4-20ma. outputs |
| |
|
Integral needle
valve and flow meter |
| |
|
Integral 3-way
valve: Sample gas, Span gas, Off |
| |
|
Patented cellblock
technology |
| |
|
Designed for Class
1, Div. I. Groups BCD (UL and
CSA approval pending) |
| |
|
|
|
|
|
|
 |
Watchdog
click
photos for larger view
|
|
|
| |
|
Low Cost Trace Oxygen Analyzer
With
Complete Sample System
|
| |
|
High-resolution single range
LCD
|
| |
|
10-user selectable
analog output ranges: 0-10ppm,
0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm,
0-.500%, 0-1%, 0-5%, 0-10% and
an air cal. range of 0-25% |
| |
|
1-5VDC or 4-20ma
analog outputs, user selectable |
| |
|
Patented cellblock technology
|
| |
|
1-2 year life electrochemical
sensor |
| |
|
Very compact and
rugged |
| |
|
Designed for Class
1, Div. II. Groups CD |
| |
|
|
|
|
|
|
|
|
Sample
Pump
click
photos for larger view
|
|
|
| |
|
Sample Pump |
| |
|
Handles wide pressure ranges
from 14"Hg. to 10psig.
|
| |
|
Designed for Class
1, Div. II Group C,D Area Classifications |
| |
|
Long life pump
and motor, 20,000 + hrs. continuous |
| |
|
Unique pump diaphragm that
is virtually non diffusive
|
| |
|
12VDC @ 700ma |
|
|
|
|
|
|
|
|
|
|
|
|
|
|