Percent
Oxygen Probe |
| |
|
Single range measurement:
0-25%, 0-50% or 0-100%
|
| |
|
0-2.5VDC and 0-4.00VDC
outputs |
| |
|
1-2 year life
electrochemical sensor |
| |
|
Great low cost OEM solution
for system integration
|
| |
|
General Purpose
Area Classification |
| |
|
Optional display/calibration
module |
|
|
|
|

|
 |
Model
65
click
photos for larger view
|
|
|
| |
|
Percent
Oxygen Probe |
| |
|
Single range measurement:
0-25%, 0-50% or 0-95%
|
| |
|
0-2.5VDC, 0-4.00VDC
or 4-20ma. output |
| |
|
Ultra stable 10-year
life zirconium oxide sensor |
| |
|
Great low cost
OEM solution for system integration |
| |
|
General Purpose
Area Classification |
| |
|
Optional display/calibration
module |
|
|
|
 |
 |
Model
70
click
photos for larger view
|
|
|
| |
|
Panel
Mount Percent Oxygen Analyzer |
| |
|
High resolution LCD
|
| |
|
Standard output
ranges: 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Optional ranges:
0-50%, or 0-95% |
| |
|
0-1VDC and 4-20ma.
output |
| |
|
10-year life zirconium
oxide sensor |
| |
|
2- fully adjustable
alarm contacts |
| |
|
General Purpose
Area Classification |
|
|
|
|
|
|
Model
111
click
photos for larger view
|
|
|
| |
|
Portable
Percent Oxygen Analyzer |
| |
|
High resolution LCD
|
| |
|
Standard output
ranges: 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Optional ranges:
0-50%, or 0-95% |
| |
|
Data logger |
| |
|
Exceptionally stable
10-year life zirconium oxide sensor |
| |
|
Needle valve and
flow meter |
| |
|
Optional pump |
| |
|
Rechargeable NiCd
batteries |
|
|
|
|
 |
 |
Model
201RS
click
photos for larger view
|
|
|
| |
|
Panel Mount Percent Oxygen Analyzer
With Sample System |
| |
|
High resolution LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
Standard output
ranges: 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Optional ranges:
0-1000ppm or 0-50% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and
flow meter |
| |
|
Span and shut off
solenoid valves |
| |
|
Patent cellblock
technology |
| |
|
General Purpose |
| |
|
|
|
|
|
|
|
|
 |
 |
Model
201RSP
click
photos for larger view
|
|
|
| |
|
Panel Mount Percent Oxygen Analyzer
With
Sample System |
| |
|
High resolution LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
Standard output
ranges: 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Optional ranges:
0-1000ppm or 0-50% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and
flow meter |
| |
|
Span and shut off
solenoid valves |
| |
|
Long life sample
pump |
| |
|
Patent cellblock
technology |
| |
|
General Purpose
|
| |
|
|
|
|
|
|
|
|
 |
 |
Model
201RSM
click
photos for larger view
|
|
|
| |
|
Panel Mount Percent Oxygen Analyzer
With
Sample System |
| |
|
High resolution LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc. |
| |
|
Standard output
ranges: 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Optional ranges:
0-1000ppm or 0-50% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and
flow meter |
| |
|
5- port solenoid
valves |
| |
|
5-point programmable
sequencer |
| |
|
Patent cellblock
technology |
| |
|
General Purpose |
| |
|
|
|
|
|
|
 |
 |
Model
201RSPM
click
photos for larger view
|
|
|
| |
|
Wall Mount Percent Oxygen Analyzer
With Complete Sample System |
| |
|
High resolution LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
alarm bypass, data logger, 3-individual
security settings, internal diagnostics,
etc |
| |
|
Standard output
ranges: 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Optional ranges:
0-1000ppm or 0-50% |
| |
|
Isolated 4-20ma.
output |
| |
|
Needle valve and
flow meter |
| |
|
Long life sample
pump |
| |
|
5- port solenoid
valves |
| |
|
5-point programmable
sequencer |
| |
|
Patent cellblock
technology |
| |
|
General Purpose |
| |
|
|
|
|
|
|
 |
 |
Model
210BR
click
photos for larger view
|
|
|
| |
|
Wall Mount Percent Oxygen Analyzer
With Complete
Sample System |
| |
|
High resolution LCD
|
| |
|
State-of the-art-
electronics platform: 2-fully
adjustable alarm set points, user
selectable alarm configurations,
data logger, 3-individual security
settings, internal diagnostics,
etc |
| |
|
Standard output
ranges: 0-1%, 0-5%, 0-10% and
0-25% |
| |
|
Optional ranges:
0-1000ppm or 0-50% |
| |
|
1-5VDC and 4-20ma.
outputs |
| |
|
Needle valve and
flow meter |
| |
|
3-way valve: Sample
gas, Span gas, Off |
| |
|
Patent cellblock
technology |
| |
|
Designed for Class
1, Div. I. Groups BCD (UL and
CSA approval pending) |
| |
|
|
|
|
|
|
|
|
| |
|
Area
Safety Monitor |
| |
|
3 ½ LCD
|
| |
|
0-25% range |
| |
|
0-1VDC or optional
4-20ma. output |
| |
|
Ultra stable 10-year
life zirconium oxide sensor |
| |
|
2- Preset dry alarm
contacts, set per OSHA standards
19.5% for danger alarm and 20.0%
for caution alarm |
| |
|
Battery back-up |
| |
|
95db audible alarm
set for 19.5% oxygen |
| |
|
General Purpose
Area Classification |
|
|
|
|
|
|
|
|
|
|
|
|
|
|